PURITY 450 Quell STPURITY 600 Quell STPURITY 1200 Quell STMDU – Measuring and Display UnitHandbook 1 Defi nition of Terms 2 General Information 3 Comm
104.2 Inserting the Filter CartridgePlace new fi lter cartridge • 2 in the pressure vessel 1.Check the connector seat of the fi lter cartrigde O-ring i
11Production dataBriefl y press button 1 x (< 1 second), the following message appears.• Serial Appliance Number Battery Service LifeID LevelProduct
12at the bottom left, the meter reading when changing the cartridge (-1) and at the bottom right, the installation date of the cartridge.Meaning: the
13Program OverviewID-InformationÀÀÀ00 Current levelÀÀÀ-1 History level 1ÀÀÀ-2 History level 2ÀÀÀ-3 History level 3ÀÀÀ-4 History level 4ÀÀÀE1 Erro
147.2 No or low water fl ow in spite of open water intakeCause: Mains pressure too low.Troubleshooting: Check mains pressure. If the fault continues, c
157.9 By-pass setting in the display does not agree with the setting of the by-pass screw (cf. 7.7/7.8 )Cause: Valve strip of the by-pass setting not
MAVEA LLC675 Tollgate Road, Suite GElgin, IL 60123 [email protected] in the instruction for use subject to changePN: 536829-M
2PURITY 450 Quell STPURITY 600 Quell STPURITY 1200 Quell ST050%102030401102187654321112141516171819209121316
32 General InformationBefore commissioning or replacing the fi lter, please read the system handbook for the PURITY Quell ST Water Filter System. There
4Temporary hardnessThe local temporary hardness in gpg (grains per gallon) set during installation of the fi lter system.Note: If necessary, the units
5ParameterisationThe following parameters have to be entered:Number of gpg (grains per gallon) or rather mg/L (CaCO3 mg/l).• Filter system size (03Typ
6Press the button (> 2 seconds) until the value for the • temporary hardness rises and keep it pressed until the desired value has been reached.>
7Press button 2 x (< 1 second) to access the next • parameter input type of hardness. Type of hardness fl ashes. > 2 sec10.12.0813gpgUSgaL1212Typ
8Carefully open fl ush valve • 9 while holding the fl ush hose in the bucket. Flush quantity once again at least 2.6 US gallons (10 litres).Close fl ush
9If the cartridge is already exhausted, the capacity is indicated as being negative by fl ashing. No bars are shown in the display.If the monthly limit